Brand Name :Purescience
Model Number :YF-E80-3
Certification :ISO14001-2000/ISO9001-2008/GB/T28001/MC01010429
Place of Origin :China
MOQ :5 sets
Price :negotiable
Payment Terms :T/T, L/C, Western Union
Supply Ability :500 sets per month
Delivery Time :3 weeks
Packaging Details :carton
Description :flow meter for water utility
Pressure :1.6Mpa
Liner material :NR / CR / PTFE liner
Flow velocity range :1-15 m/s
Pressure rating :PN16, PN25, PN40 Mpa
Accuracy :+/1 0.5% R
Pipe Dia. :DN25-DN300
Connect port :Flange
Enclosure protection :IP65
Power supply :100-240 VAC / 18-36 VDC
Contact Now

Add to Cart

Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
View Product Description

Electromagnetic flowmeter for municipal water utility Liner: PTFE, Pressure DN80

Product Description

The electromagnetic flow meter, is available with size DN25 - DN1200, it's combined by a flow sensor and transmitter into one convenient package. It incorporates rugged carbon steel construction with flanges creating a versatile, user-friendly flow metering system for general purpose applications involving clean, sanitary, dirty, corrosive and abrasive liquids. The system is IP65 rated for protection from dust and low pressure water jets.

Data sheet

Product name

Electromagnetic flowmeter

Product type

Local|compact display

Remote display

Signal converter

Model

IYF-E

IYF-F

IRT

Pipe Diameter (mm)

DN10-DN2000

Power supply

100-240 VAC / 18-36 VDC

Accuracy

+ 0.5%

+ 0.5%

+ 0.5%

Power consumption

<6w

<6w

<6w

Enclosure rating

IP65

IP68

IP65

Liquid temperature

-25-120℃

-25-120℃

-25-120℃

Ambient temperature

-25-50℃

-25-50℃

-25-50℃

Relative humidity

10-90%

10-90%

10-90%

Meter ratio

1:100

1:100

1:100

Flow direction

Bi-direction flow

Bi-direction flow

Bi-direction flow

Communication

RS485 / Bacnet

RS485 / Bacnet

RS485 / Bacnet

Signal Output

4-20mA/Pulse/Frequency

4-20mA/Pulse/Frequency

4-20mA/Pulse/Frequency

Features

  • Virtually no pressure loss
  • Suitable to meter for wide range of conductive liquid media
  • No Moving Parts
  • Flanges port connection
  • RS485 Standard
  • Suitable for Pipes diameter p to 2000 mm
  • Large meter ratio
  • High Accuracy
  • 4 to 20 mA / Frequency / Pulse output

Accuracy

Pipe Dia (mm) Velocity (m/s) Accuracy
3-20 <0.3 + 0.25% FS
0.3-1 + 1.0% Readout
1-15 + 0.25% Readout
25-600 0.1-0.3 + 0.25% FS
0.3-1 + 0.5% Readout
1-15 + 0.3% Readout
700-3000 <0.3 + 0.25% FS
0.3-1 + 1.0% Readout
1-15 + 0.25% Readout

Grounding

From flow meter housing terminal G to grounding by minimal 1.6mm2 copper cable, resistivity < 10 Ω.

Model selection

Applicable metering liquid:

  • Conductive liquid media, conductivity > 5 µS/ cm
  • Various Conductive aqueous solutions, water solutions, acid & caustics
  • Abrasive slurries, sludges and grease bearing liquids, corrosive liquid, municipal tap water, waste water,dirty
    water, effluent, fibrous, viscous, paper mill, food & beverage

Non-applicable metering medial

  • Industrial gas, compressed air, steam, or liquid with large content of gas
  • Liquid is non-conductive or low conductive, like lubricating oil, clean oil, cryogenic, cooling water, pure
    water, clean gas, etc.

Notice on the selection of local type and remote type:

Remote type means the transmitter and converter display are mounted in different locations, it’s suggested to select
remote type in the following conditions:

  • Ambient temperature or converter display sunshine temperature is over 60 ℃
  • High humidity or corrosive air existed
  • Serious pipe vibration
  • Magnetic meter need be suspended or submersible, uneasily read out
  • Other abrasive condition

I

Model

YF

Electromagnetic flowmeter

TF

Turbine

VF

Votex

LX

Vane wheel

T

Ultrasonic

E/F display mode

E: compact/local display, F: remote display

Pipe Dia

Type (mm)

xxxx

15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300, 400,

500, 600, 800, 1000

Code

Accuracy

1

+ 0.5% FS

2

+ 1.0% FS

3

+ 0.2% FS

Code

Type

N

Converter: 12 / 24 VDC, pulse output

A

Transmitter: 24VDC, 4-20mA outpt

B

Intelligent, Lion battery, no local display

G

Smart, local display, 4-20mA output

C1

Smart, local display, RS485

C2

Smart, local display, HART

Code

Type

S

Carbon steel housing

L

Stainless steel housing

G

High pressure housing

HL

316L electrode

HTi

Titanium electrode

HTa

Tantlum electrode

HC

Hastelloy-C electrode

L1

Liquid media

L2

Gas media

P

Pressure compensation

T

Temperature compensation

PT

Pressure&Temp. Compensation

F

PTFE liner

X

Rubber liner

Sample: IYF-E-0100-1-C1-S-HL-L1-F, Magmeter, local display, Dia: 100mm, + 0.5%FS, carbon steel housing,

smart, 4-20mA outpt, RS485, 316L electrodes, liquid media meter, PTFE liner

Pipe Diameter, flow volume and product dimension

Dia

Flow volume (m3/h)

Product dimension (mm)

(mm)

Normal

Min

Max

L

D

H

H1

15

1.5

0.06

9.5

150

95

272

254

20

2.5

0.11

16.9

105

277

254

25

3.5

0.18

26.5

115

283

254

32

6

0.29

43.6

140

297

270

40

10

0.45

67.8

150

307

280

50

15

0.71

106.0

200

165

318

294

65

25

1.19

179.1

185

337

313

80

40

1.81

271.4

200

352

326

100

60

2.83

424.1

250

220

371

344

125

100

4.42

665

250

401

372

150

135

6.36

954

300

285

431

403

200

250

11.3

1696

350

340

486

460

250

375

17.66

2650

400

395

547

511

300

540

25.43

3817

450

445

597

565

350

735

34.62

5195

505

657

620

400

960

45.22

6785

500

565

717

675

450

1200

57.23

8588

550

615

757

727

500

1500

70

10602

600

670

817

782

600

2160

100

15268

780

917

782

700

2950

138

20781

700

895

1027

1068

800

3850

180

27100

800

Product Tags:

China Municipal Magnetic Flow Meter Pressure Dn80 1.6mpa With High Accuracy for sale

Municipal Magnetic Flow Meter Pressure Dn80 1.6mpa With High Accuracy

Inquiry Cart 0