Multi jet water meter by rotary piston theory Rotary register brass DN15
This rotary piston water meter is with rotary register, it's for volumetric measurement of cold potable water.
Feature:
Note:
Working condition:
Maximum Permissible Error:
(1) Between qt (included) and qs is ±2%;
(2) Between qmin and qt (excluded) is ±5%.
Flow error curve
Data sheet
Description | Unit | Hydraulic data and dimensions | ||
Nominal size | mm(inch) | DN15 (1/2") | DN20(3/4") | |
Overload flow rate (Qs) | m3/h | 2 | 3 | |
Permeanent flow rate (Qp) | m3/h | 1 | 1.5 | |
Transitional flow rate (Qt) | l/h | 80 | 120 | |
Minimum flow rate (Qmin) | l/h | 20 | 30 | |
Min reading | l | 0.05 | 0.05 | |
Max reading | l | 99999.9999 | 99999.9999 | |
Max work pressure | MPa | 1.6 | 1.6 | |
Pressure difference at Qs | Mpa | <0.1 | <0.1 | |
L | mm | 165 | 190 | |
I | mm | 245 | 290 | |
H | mm | 135 | 135 | |
h | mm | 36.5 | 36.5 | |
B | mm | 94 | 94 | |
D | inch | G3/4B | G1B | |
d | inch | R1/2 | R3/4 | |
weight | with connections | kg | 1.49 | 1.75 |
without connections | 1.29 | 1.45 |
Competitive Advantage:
Production line
Base water meter