Add to Cart
electromagnetic flowmeter for sewage water Diameter: 5" - 48", Pressure: PN10/16/40.
General description
The sewage flow meter delivers the industry’s widest range of liners, electrodes and sizes to meet the needs of even the most demanding process applications in sectors as diverse as chemical, power, oil & gas and metals & mining. The powerful transmitter is easy to use and provides the output signal that meets your needs. With EPD30 you get a versatile, reasonably priced, most accurate flow meter tailored for your applications. A flowmeter with base functionality, short delivery and a simple and clearly understandable documentation
Technical parameters:
Application
Waster water industry: transport networks sewage treatment plants, sludges;
Chemical industry: acids alkalis, dosing applications, abrasive or corrosive mediums;
Metal & mining industry: mediums with a high solid content,like one or excavator mud;
Water industry: Revenue metering, district metering water abstraction, leakage detection;
Pulp &paper industry: pulp, pastes, sludges & other caustic mediums, liquor, additives, bleaches,colourants;
Food & beverage industry: mixing, dosing and filling of drinks under hygienic conditions filling systems applications.
Parameters
Product name | Electromagnetic flowmeter | ||
Product type | Local|compact display | Remote display | Signal converter |
Model | IYF-E | IYF-F | IRT |
Pipe Diameter (mm) | DN10-DN2000 | ||
Power supply | 100-240 VAC / 18-36 VDC | ||
Accuracy | + 0.5% | + 0.5% | + 0.5% |
Power consumption | <6w | <6w | <6w |
Enclosure rating | IP65 | IP68 | IP65 |
Liquid temperature | -25-120℃ | -25-120℃ | -25-120℃ |
Ambient temperature | -25-50℃ | -25-50℃ | -25-50℃ |
Relative humidity | 10-90% | 10-90% | 10-90% |
Meter ratio | 1:100 | 1:100 | 1:100 |
Flow direction | Bi-direction flow | Bi-direction flow | Bi-direction flow |
Communication | RS485 / Bacnet | RS485 / Bacnet | RS485 / Bacnet |
Signal Output | 4-20mA/Pulse/Frequency | 4-20mA/Pulse/Frequency | 4-20mA/Pulse/Frequency |
Measure Accuracy
Pipe Dia (mm) | Velocity (m/s) | Accuracy |
3-20 | <0.3 | + 0.25% FS |
0.3-1 | + 1.0% Readout | |
1-15 | + 0.25% Readout | |
25-600 | 0.1-0.3 | + 0.25% FS |
0.3-1 | + 0.5% Readout | |
1-15 | + 0.3% Readout | |
700-3000 | <0.3 | + 0.25% FS |
0.3-1 | + 1.0% Readout | |
1-15 | + 0.25% Readout |
Applications:
Irrigation, clean water, paper pulp, slurry, sewage, waste water, HVAC/R system monitoring, residential water meter, industrial & commercial water utilities